The single jacket fiber optic cable’s composition consists of several key components. A 250μm optical fiber is securely housed within a high modulus loose tube, further reinforced with a waterproof compound for with FRP (Fiber Reinforced Plastic) central core, providing structural stability.

To create a compact, rounded cable core, the loose tube and filler rope are carefully twisted around the central reinforcing core, ensuring the cable’s shape and integrity.

Gaps within the single jacket cable core are diligently filled with a water-blocking filler, safeguarding the optical fibers from moisture.

Additionally, a longitudinally applied corrugated plastic-coated steel tape (PSP) enhances the cable’s resistance to external forces and environmental conditions. The cable is sealed with a polyethylene sheath, adding further protection and insulation.

Single Jacket Fiber Optic Cable
Structure Design:
  • Central strength member (CSM): FRP rod

  • Fiber 12-288F IUT-T G652D (A1 & A2 Glass options are available)

  • Loose tube containing fibers and filled with a suitable water tightness filling compound

  • Longitudinal water tightness: dry core with water swellable yarns

Highlights:
  • All-dielectric: Requires no grounding or bonding

  • Key Components: 250μm optical fiber in a high modulus loose tube with waterproof reinforcement.
  • Core Stability: Non-metallic FRP central core for structural stability.

  • Compact Design: Twisted loose tube and filler rope maintain shape and integrity.
  • Moisture Protection: Water-blocking filler safeguards optical fibers.

Specifications:
Fiber Count 12 24 48 72 96 144 288
Fiber counts per tube 6 6 12 12 12 12 12
Loose Tube Counts 2 4 4 6 8 12 24
Diameter (mm) 1.8 1.8 2.1 2.1 2.1 2.1 2.1
Material PBT
Water Blocking Tube filling compound
Central Strength Member Material FRP
Size (mm) 2.0 2.0 2.2 2.0 2.2 3.0 3.2
Outer Jacket Material HDPE, Black
Nominal Thickness (mm) 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Temperature Range Operation -30°C~+70°C
Storage -20°C~+60°C
Installation -10°C~+70°C
Optical Characteristics:
Attenuation Coefficient @1310nm ≤ 0.35 dB/Km
@1550nm ≤ 0.21 dB/Km

*Full compliance with the ITU-T G.652D Standard

Mechanical Performance:
  • Minimum bending radius Static 10D and 15D Dynamic (D is the cable diameter in mm)

Color Code:

The individual fibers and loose tubes comply with the TIA/EIA-598-A Standard.